Drive Parametrization

Top  Previous  Next

 

The following parameters must be set as below:

 

Drive

Connection Type

Parameter

Description

Recommended

SSW-06

RS232

308

SSW Address

1

309

Fieldbus

0: Inactive

312

Serial Protocol

1: MB 9600 N

(Modbus-RTU 9600 bps, no parity)

SSW-07

RS232

308

SSW Address

1

312

Serial Protocol

1: MB 9600 N

(Modbus-RTU 9600 bps, no parity)

CFW-09 PM

RS232

308

Serial:Address

1

310

Serial:Bit Rate

1: 9600 bps

311

Serial:Data Con.

3: 8b,no p,2sb

312

Serial:Protocol

2: Modbus-RTU

CFW-11

USB

-----

-----

-----

 

Note

Drive and SuperDrive G2 must use the same settings.

 

For SSW, P308 and P312 can be changed, see Serial Communication Manual.

 

For CFW-09 PM, P308, P310 and P311 can be changed, see Frequency Inverter Manual - CFW-09 PM.